Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
W/two i-beam clamps, rods, fittings for installaition of heater to ceiling and w/multi-cone anemostat diffuser
NSN
National Stock Number:
TXT
Description:
Stea Air Circulating Unit Heater
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Ceiling suspended
MRC:
Indicates the heat medium type for which the unit is designed.ABAM
Heat Medium Type:
Air
MRC:
Indicates the limit of the maximum pressure for which the item is designed.ABAN
Maximum Pressure Limit:
350.0 pounds per square inch gage
MRC:
The number of heat outlets included on the item.ABAW
Heat Outlet Quantity:
1
MRC:
The direction in which the heat is discharged from the item.ABAX
Heat Delivery Direction:
Horizontal
MRC:
Indicates the type of outlet(s) provided for the discharge of heat.ABAY
Heat Discharge Outlet Type:
Adjustable
MRC:
Indicates the device/s/ provided for the purpose of directing the flow of heat.ABAZ
Heat Directing Device:
Adjustable louver
MRC:
The mechanism used for air circulation.ABBA
Air Circulation Device:
Propeller fan
MRC:
The different speeds at which the item may be operated.ABBB
Speed Adjustments:
Single speed
MRC:
Indicates the type of air the item is designed to circulate.ABBE
Circulated Air Type:
Heated
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of device which controls the operation of the item.ALYC
Operating Control Type:
Thermostatic
MRC:
Indicates the type of heating element provided.BDXJ
Heating Element Type:
Steam coil
MRC:
The chemical compound or mechanical mixture properties of which the inclosure is fabricated.CQSJ
Inclosure Material:
Steel
MRC:
The rate of heat delivery of the item.CQXD
Heat Delivery Rate:
108000.0 british thermal unit
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
A numeric value which represents a positive whole value without regard to any unit of measure.NMBR
Quantity:
1
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
1 type
MRC:
The technical differentiating characteristic/s/ of an item of supply which depart/s/ from the text of a specification or a standard in that it represents a selection of characteristics stated in the specification or standard as being optional,or a variation from one or more of the stated characteristics,or an additional characteristic not stated in the specification or standard.ZZZW
Departure From Cited Document:
As modified by maximum pressure limit and special features