Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Fluid Pressure Regulating Valve
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Steel, astm a216, grade wcb
First End Flange Outside Diameter:
6.500 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight thru
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Steam
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Raised face flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Raised
First End Raised Face Height:
0.250 inches
First End Raised Face Diameter:
3.625 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the shape of the end flange.ACKT
First End Flange Shape Style:
Round w/ bolt holes
MRC:
A measurement of the smallest dimension of the first end flange, in distinction from length or width.ACKU
First End Flange Thickness:
0.562 inches
MRC:
The number of bolt holes provided on the item.ACKZ
First End Bolt Hole Quantity:
8
MRC:
The length of a straight line which passes through the center of a bolt hole,and terminates at the circumference.ACLA
First End Bolt Hole Diameter:
0.875 inches
First End Bolt Circle Diameter:
5.000 inches
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
Face To Face Distance:
10.250 inches
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Disk, guided
MRC:
The element,compound,or mixture of which the flow control device is fabricated.ADQV
Flow Control Device Material:
Steel
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
The minimum to maximum limits of outlet pressure of the item.AEVA
Outlet Pressure Range:
+100.0/+450.0 pounds per square inch
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
Automatic single stage
MRC:
The means of providing resistance to the media passing through a valve,whereby the valve is actuated to regulate the flow.AEVR
Valve Loading Method:
Spring
MRC:
The maximum pressure of the media on the inlet side at which an item is designed to operate.AEVZ
Maximum Inlet Pressure Rating:
600.0 pounds per square inch
MRC:
An indication of whether or not a filter is included.AEWF
Filter:
Not included
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
A class and d composition