Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Motor-generator
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
42.500 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
68.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
36.250 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac input
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Dripproof-15 degrees and dripproof-15 deg
MRC:
The means of attaching the item.AXGY
Mounting Method:
Bed plate
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Mil-std-108
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Horizontal mounting position
MRC:
The amount of electrical energy that can be dissipated.CNXS
Power Rating:
82.0000 horsepower output
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
75.0 ambient degrees celsius
MRC:
The speed rating of a rotor,expressed in revolutions per minute.CWFX
Rotor Speed Rating In Rpm:
1200.0 single full load
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
208.0 line to line single output or 120.0 line to neutral single output
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
220.0 line to neutral first multiple input or 440.0 line to neutral second multiple input
MRC:
The number of alternating current phases.FAAZ
Phase:
Three input
MRC:
The number of alternating current phases.FAAZ
Phase:
Three output
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
400.0 output
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 input