Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
milr12574
Demil:
No
Shelf Life:
UOM:
NIIN:
000825832
NSN
National Stock Number:
4110-00-082-5832 4110000825832
TXT
Description:
Mechanical Refrigeration Unit
INC
INC
Item Name Code:
13501
MRC:
The capacity of the item as rated by industry,expressed in british thermal units /btu/ of refrigeration per hour.AGUB
Refrigeration Capacity In Btu Per Hour:
5000.0
MRC:
An indication of the rated horsepower of the item.ANCY
Horsepower Rating:
5.000
MRC:
Indicates the type of unit.APQB
Unit Type:
Panel
MRC:
Indicates the type of control.AQZF
Control Type:
Manual
MRC:
Indicates the type of coolant used with the item.ARNA
Coolant Type:
Freon-12
MRC:
Indicates the type of condenser.AWLP
Condenser Type:
Open
MRC:
Indicates the type of drive provided for the fan.AWMB
Fan Drive Type:
Compressor unit prime mover
MRC:
The storage capacity of the item.AXWT
Err Default:
Err default
MRC:
The storage capacity of the item.AXWT
Storage Capacity:
150.0 cubic feet
MRC:
Indicates the type of cooling for which the condenser is designed.AZAD
Condenser Cooling Type:
Air
MRC:
Indicates the location in the item where the unit is inserted.AZDP
Unit Insertion Location:
Side
MRC:
An indication of whether or not a panel unit skid mounting feature is included.AZDY
Err Default:
Err default
MRC:
An indication of whether or not a panel unit skid mounting feature is included.AZDY
Panel Unit Skid Mounting Feature:
Not included
MRC:
Indicates the type of evaporator unit.AZEA
Evaporator Unit Type:
Forced air-cooling
MRC:
Indicates the type of drive used for the evaporator fan.AZEL
Evaporator Fan Drive Type:
Condensing unit prime mover
MRC:
Indicates the type of defrost system for which the item is designed.AZJY
Defrost System Type:
Hot gas
MRC:
Indicates the type of drive for which the compressor is designed.AZKH
Compressor Drive Type:
Electric motor
MRC:
Indicates the type of current required to operate the motor.AZKJ
Motor Current Type:
Ac
MRC:
The total electrical voltage of the motor,expressed in volts.AZKK
Motor Voltage In Volts:
208.0
MRC:
The number of complete cyclic changes,per unit of time,for which the motor is rated.AZKL
Motor Frequency Rating:
60.0 hertz
MRC:
The number of alternating current phases of the motor.AZKM
Motor Phase:
Three
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.AZKQ
Tempurature Rating:
0.0 degrees fahrenheit
MRC:
The temperature of the medium surrounding an item at which it can be operated,expressed in degrees fahrenheit.AZKR
Err Default:
Err default
MRC:
The temperature of the medium surrounding an item at which it can be operated,expressed in degrees fahrenheit.AZKR
Ambient Tempurature Rating In Deg Fahrenheit:
110.0
MRC:
An indication of whether or not radio interference suppression is included.AZKT
Radio Interference Suppression:
Included
MRC:
The specification and/or standard used to control the nature and degree of radio interference suppression.AZKW
Err Default:
Err default
MRC:
The specification and/or standard used to control the nature and degree of radio interference suppression.AZKW
Radio Interference Suppression Specification/std:
Mil-std-461, class iib
MRC:
A measurement taken at right angles to the length of the sealing surface of the insert plug,in distinction from thickness.BBLL
Err Default:
Err default
MRC:
A measurement taken at right angles to the length of the sealing surface of the insert plug,in distinction from thickness.BBLL
Insert Plug Sealing Surface Width:
28.500 inches
MRC:
A measurement from the bottom to the top of the sealing surface of an insert plug,in distinction from depth.BBLM
Err Default:
Err default
MRC:
A measurement from the bottom to the top of the sealing surface of an insert plug,in distinction from depth.BBLM
Insert Plug Sealing Surface Height:
28.500 inches
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
Ii type