Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Meter Movement Relay
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
5
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Solder wire
MRC:
The standard of valuation as represented by the inscription.ABWC
Scale Unit Of Measure Inscription:
Milliamperes
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Metal
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Humidity resistant and salt spray resistant
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Three 0.5 in. Lg studs by 0.112 in. Diameter equally spaced on a 2.44 in. Circle
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
150.0 volts
MRC:
The minimum and maximum numeric values representing the measurement coverage of a scale.ANSZ
Scale Measurement Range:
+0.0/+150.0
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the main contacts including the number of poles or forms.APDZ
Main Contact Arrangement:
1 pole, single throw, both positions maintained
MRC:
Indicates the type of current used by the main contact/s/.APEB
Main Contact Current Type:
Dc
MRC:
The current rating of the main contact/s/.APEC
Main Contact Current Rating:
Between 10.0 milliamperes and 25.0 milliamperes
MRC:
Indicates the type of current used in the meter movement.APGN
Meter Movement Current Type:
Dc
MRC:
An indication of the minimum and maximum amount of current used in the meter movement.APGR
Meter Movement Current Range:
+0.0/+150.0 milliamperes
MRC:
An indication of the direction of the meter movement reading range.APGT
Meter Movement Range Direction:
Left to right
MRC:
Indicates the type of mount utilized to support the meter.APMR
Meter Mounting Type:
Surface
MRC:
An indication of the specific condition that causes the contacts to close.APMT
Contact Closing Condition:
Increase value
MRC:
An indication of whether or not the reset facilities are provided.APNR
Reset Facility Feature:
Not provided
MRC:
Indicates the type of lock in device provided.APNS
Lock In Device Type:
Locking coil
MRC:
The means by which the item is released.APNT
Release Method:
Manual or electromagnetic