Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Circuit Breaker
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Single pole type
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.250 inches
MRC:
The center to center distance between terminals parallel to the length of the item.AEBP
Center To Center Distance Between Terminals Parallel To Length:
1.137 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Sea king helicopter ch124a
Mounting Surface To Terminal End Distance:
1.812 inches
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
32
MRC:
The maximum current load that each pole is rated to carry continuously.CPLM
Maximum Continuous Load Current Rating Per Pole:
10.0 amperes ac single location and 10.0 amperes dc single location
MRC:
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.CPRF
Operating Voltage Type And Rating Per Pole In Volts:
120.0 ac single location and 30.0 dc single location
MRC:
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.CPRG
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
600.0 ac single location and 6000.0 dc single location
MRC:
The temperature of the medium surrounding the trip release at which it can be operated continuously.CRCF
Trip Release Ambient Tempurature Rating:
25.0 degrees celsius single location
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 tab w/screw