Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
msca14
Demil:
No
Shelf Life:
UOM:
NIIN:
012022048

Part Information
Reference number differentiating material will be in accordance with naval inventory control point activity hx quality control. Manufacturing and testing specifications available at the dla icp. Item must comply with requirements of defense supply center columbus production standard no. Lo5085; paint aluminum tt-p-320 on armor

NSN
National Stock Number:
6145-01-202-2048 6145012022048
TXT
Description:
Electrical Power Cable
INC
INC
Item Name Code:
00232
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
0.692 inches
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
14
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
7 all conductors
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded all conductors
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
18 awg all conductors
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
26 all conductors
MRC:
The arrangement and number of arrangements of the conductors.CXDQ
Conductor Arrangement And Quantity:
14 singles
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
1000.0 root mean square (rms) operating voltage all conductors
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Astm b3 assn standard single material response core conductor all conductors

Similar Electrical Power Cables

« Wire and Cable, Electrical Catalog
Compare Now »
Clear | Hide