Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
The shaft of this motor is a combination of 2 styles - (flat keyway, and two flats at 90 degrees). The two flats are closer to the motor than the keyway - the are 0.029 in. Deep and 0.630 in. Long. The keyway starts 0.500 in. From the end of the shaft and extends to the end of the shaft
NSN
National Stock Number:
TXT
Description:
Motor-tachometer Generator
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
2.980 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
7.040 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
2.250 inches
MRC:
A measurement taken at right angles to the length of a keyway,in distinction from thickness.ABRR
Keyway Width:
0.094 inches single end
MRC:
A measurement from the top surface to the bottom of the keyway groove.ABRV
Keyway Depth:
0.048 inches single end
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.374 inches single end
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc input
MRC:
A measurement of the longest dimension of a keyway,in distinction from width.AFYS
Keyway Length:
0.500 inches single end
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Totally enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Face
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 threaded hole
MRC:
Indicates the type of excitor provided.AYHE
Excitor Type:
Separately excited
MRC:
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.BBRG
Storage Type:
General purpose warehouse
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Ambient air
MRC:
An indication of the type of calibration voltage output,expressed in volts.BKPC
Calibration Voltage Output Type In Volts:
7.0 ac
MRC:
Indicates the torque rating,and its type.BKPH
Torque Rating And Type:
100.0 inch-ounces stalled
MRC:
The amount of electrical energy that can be dissipated.CNXS
Power Rating:
295.0 watts input
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
1.940 inches single end
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
34.7 line to neutral single input
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A9 single style single end
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 receptacle