Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
mw1145a1
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
007142461

Part Information
Double wall; o/a dim 27 in. L, 14 in. W, 16 in. D; built-in automatic circulating system; solid state power supply; 23.5 in. Diameter temp indicator

NSN
National Stock Number:
6640-00-714-2461 6640007142461
TXT
Description:
Constant Temperature Bath
INC
INC
Item Name Code:
32951
INC
COM
Compliance:
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
Inside Width:
7.500 inches
MRC:
A measurement of the longest inside dimension of an item,in distinction from width.ADJU
Inside Length:
12.000 inches
MRC:
The number of covers furnished with the item.AEMW
Cover Quantity:
1
MRC:
An inside measurement between specified points of an item,in distinction from height.AFEF
Inside Depth:
7.500 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+5.0/+260.0 degrees celsius
MRC:
An indication of whether or not an insulated feature is included.AHGR
Insulated Feature:
Included
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
120.0 volts
MRC:
A measurement of the capacity of an item.BBLT
Capacity Rating:
3.500 gallons
MRC:
The rated power that an item can safely consume or provide.BDWW
Wattage Rating:
1.4 kilowatts
MRC:
The element,compound,or mixture of which the reservoir is fabricated,excluding any surface treatment.BNDF
Reservoir Material:
Steel
MRC:
An indication of whether or not the reservoir is removable.BNDG
Reservoir Removability:
Nonremovable
MRC:
An indication of whether or not an agitator is included.BNDQ
Agitator:
Included
MRC:
An indication of whether or not a pilot light is included.BNDY
Pilot Light:
Included
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The physical configuration of the item.SHPE
Shape:
Rectangular