Part Number MX-8-263

Electrical Solenoid
Description

Solenoid

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
mx-8-263
Demil:
No
Shelf Life:
UOM:
NIIN:
009013764
NSN
National Stock Number:
5945-00-901-3764 5945009013764
TXT
Description:
Electrical Solenoid
INC
INC
Item Name Code:
00310
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2b mounting facility hole
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2b power takeoff facility hole
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Cylindrical frame
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
0.500 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.500 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Aluminum
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.ADTY
Case Surface Treatment:
Anodized
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Dustproof and explosion proof
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
195.0 degrees fahrenheit
MRC:
The measurement of the distance that the actuator protrudes from the body.AFGK
Actuator Length:
0.047 inches
MRC:
The length of a straight line which passes through the center of the actuator,and terminates at the circumference.AFUR
Actuator Diameter:
0.250 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of magnetic coils provided.APAF
Magnetic Coil Quantity:
1
MRC:
A measurement of the opposition to the flow of direct or alternating current.APCC
Electrical Resistance:
11.00 ohms
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Intermittent
MRC:
The voltage rating at which the item is designed to operate,expressed in volts.ASXH
Voltage Rating In Volts:
29.0 dc
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 threaded hole
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
48 mounting facility hole
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
48 power takeoff facility hole
MRC:
The movement of the actuator when force is applied.CNXT
Actuator Stroke Type:
Pull
MRC:
Indicates the type of means provided for connection of the power takeoff.CNXX
Power Takeoff Connection Type:
Internal threads
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.099 inches mounting facility hole
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.099 inches power takeoff facility hole
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
11871-320-963-1 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc mounting facility hole
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc power takeoff facility hole
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead

Similar Electrical Solenoids

« Relays and Solenoids Catalog
Compare Now »
Clear | Hide