Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
myh700ta3-2159sc1449s
NSN
National Stock Number:
TXT
Description:
Refrigeration Compressor
MRC:
The media the machine is designed to compress.AAXK
Gas For Which Designed:
Refrigerant r-22
MRC:
The rated capacity of gas delivered by the last stage of compression.AAXL
Discharge Flow Rate:
7.000 cubic feet per minute
MRC:
The gage pressure of gas delivered by the last stage of compression. referred to as condensing pressure for refrigeration compressors.AAXM
Discharge Pressure:
228.700 pounds per square inch gage
MRC:
The design of the system necessary to maintain the required operating temperature of an item and discharge temperature of the compressed gases.AAXP
Cooling System Design:
Mixed
MRC:
The cooling medium used to maintain the required operating temperature of the compressed gases.AAXQ
Compressed Gas Cooling Medium:
Air
MRC:
The cooling medium used to maintain the required operating temperature of the compressor.AAXR
Compressor Cooling Medium:
Refrigerant
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
The refrigeration capacity of the item as rated by industry,expressed in tons per hour.AAYE
Refrigeration Flow Rate In Tons Per Hour:
1.5
MRC:
The pressure of the gas after it has passed through the evaporator and prior to its compression within the item.AAYF
Suction Pressure:
69.0 pounds per square inch
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Solder tube
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Solder tube
MRC:
Indicates the type of connection between the prime mover and the shaft.AAYX
Drive Connection Type:
Cam
MRC:
The degree of heat or cold as applied to the function of the item.CSFH
Tempurature Rating Per Function:
65.5 degrees celsius discharge and 15.6 degrees celsius suction