Part Information
Reader system kodak point of care cr 140

NSN
National Stock Number:
6525-01-593-1919 6525015931919
TXT
Description:
Computed Radiography Reader
INC
INC
Item Name Code:
77777
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
29.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
13.400 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
25.800 inches
MRC:
The minimum and maximum temperatures at which an item can be stored without detrimental effect.AFJQ
Storage Tempurature Range:
-15.0/+60.0 degrees celsius
MRC:
The amount of current for which the item is designed.ARAG
Current Rating:
2.000 amperes
MRC:
The measured weight of an item unencumbered by packaging or packing material.AWJN
Unpackaged Unit Weight:
99.000 pounds
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Computed radiography reader; single-plate cr reader; flexible phosphor screens; throughput up to 40 cassettes per hour; grayscale resolution acquisition; 12 bits per pixel display; approx. Weight: 99 lb; computer workstation requirements: pentium 4.3 ghz or higher, 1 gb memory, four usb 2.0 ports, cd-rw, 83 gb or larger hd, windows xp professional os or windows vista buisiness os (small form factor chassis required for z-cart); software integrated acquisition including: image analysis, archiving, and seamless remote image communications; dicom 3.0 software platform; power requirements: single-phase 50/60 hz, 200 va, 100-240 vac (+/- 10 pct), 2 a, ups required; operating temperature: 10-40 degrees c, 90 pct at 35 degrees c; storage temperature: -15-60 degrees c; system configurations: desktop, z-cart (mobile cart), distributed cr