Part Number P-32471-06

Flow Rate Indicating Meter

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
p-32471-06
Demil:
No
Shelf Life:
UOM:
NIIN:
015053781

Part Information
Max operating temp: 116 degrees celsius (inavy) flowmeter

NSN
National Stock Number:
6680-01-505-3781 6680015053781
TXT
Description:
Flow Rate Indicating Meter
INC
INC
Item Name Code:
38346
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
10.625 inches
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Air
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Threaded
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Panel tube assembly; asds non-soc retail stock
MRC:
An indication of whether or not an integral safety device is included.AHZU
Integral Relief Valve:
Not included
MRC:
An indication of the type of meter.ANTH
Meter Type:
Float
MRC:
Indicates the design type of the item.APGF
Design Type:
Glass
MRC:
Indicates the type of unit.APQB
Unit Type:
Mounted
MRC:
The number of scales on the item.APSJ
Scale Quantity:
1
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Threaded
MRC:
An indication of the marking(s) on the scale.ASTW
Scale Marking:
Standard cubic feet per minute
MRC:
Indicates the type of scale.ATEQ
Scale Type:
Direct capacity reading
MRC:
The number of floats provided.AWAE
Float Quantity:
1
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Plastic
MRC:
The means of attaching the item.AXGY
Mounting Method:
Surface panel
MRC:
The minimum and maximum markings on a dial scale.BHBY
Dial Scale Marking Range:
+4.0/+48.0
MRC:
Designates the size of the outlet connection included on the item.BHCM
Outlet Connection Size:
0.750 inch np (male)
MRC:
Indicates the type of float used.BHSQ
Float Type:
Guided
MRC:
The element,compound,or mixture of which the float is fabricated,excluding any surface treatment.BJDM
Float Material:
Steel, stainless
MRC:
Indicates the type of guide provided.BMHW
Guide Type:
Solid rod
MRC:
An indication of whether or not an integral heat source is included.BNHN
Integral Heat Source:
Not included
MRC:
The maximum working pressure at which an item is designed to operate.BPHD
Maximum Working Pressure:
150.0 pounds per square inch
MRC:
Designates the size of the inlet connection included on the item.CPZD
Inlet Connection Size:
0.750 inch np (male)
MRC:
The number of metering tubes provided.CPZF
Metering Tube Quantity:
1
MRC:
An indication of whether or not a dial scale reference pointer is included.CPZK
Dial Scale Reference Pointer:
Not included
MRC:
The number of floats in each tube.CPZL
Float Quantity Per Tube:
1
MRC:
An indication of whether or not a spinning float is included.CPZM
Spinning Float:
Not included
MRC:
An indication of whether or not an integral pulsation dampener is included.CPZN
Integral Pulsation Dampener:
Not included
MRC:
The inlet connection position for which the item is designed.CPZP
Inlet Connection Position For Which Designed:
Vertical
MRC:
The outlet connection position for which the item is designed.CPZR
Outlet Connection Position For Which Designed:
Vertical
MRC:
An indication of whether or not an alarm signal is included.CPZT
Alarm Signal:
Not included

Similar Flow Rate Indicating Meters

« Liquid and Gas Flow, Liquid Level and Mechanical Motion Measuring Instruments Catalog
Compare Now »
Clear | Hide