Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Sealed drycellk rugged military construciton; same design used in armored vehicles; designed for standard 23 inch battery racks but may be mounted in any orientation; terminals 3/8inch stainless steel studs
NSN
National Stock Number:
TXT
Description:
Storage Battery
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
2
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
22.100 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
12.440 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.920 inches
MRC:
The composition of the electrolyte used in the battery.AEXT
Battery Electrolyte:
Lead acid
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Fire and rescue vehicles; marine; refrigerated trailers; rv motor coaches; surveillance vehicles
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
Military grade; ruggedized construction; explosion proof
MRC:
The approximate shelf life /storage time/ of the item.AQGP
Approximate Shelf Life:
15.0 years
MRC:
An indication of whether or not a nonspilling feature is included.AQHD
Nonspilling Feature:
Included
MRC:
An indication of whether or not an integral charging facility is included.AQHJ
Integral Charging Facility:
Included
MRC:
Indicates the type of design which describes the case.CWFH
Case Design Type:
Sealed
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
12.0
MRC:
Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
Special Test Features:
For heavy duty deep cycle applications
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
May be used in parallel; 214ahr at 20/hr rate-190ahr at 10/hr rate; reserve capacity-475 min at 25amps; cranking amps-1800hca, 1600 hca, 1450 mca, 1300 cca; short circuit current-3800amps; valve-regulated lead-acid (vrla)