Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Doserae electronic personal dosimeter
NSN
National Stock Number:
TXT
Description:
Radiacmeter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.900 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.900 inches
MRC:
The means of attaching the item.ADJH
Mounting Method:
Clip
MRC:
An indication of whether or not a container from which the item is completely removable in normal operable condition is provided.AFJU
Carrying Case:
Not provided
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Included
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Audio and visual
MRC:
Indicates the type of detecting element included.AMRX
Detecting Element Type:
Geiger tube
MRC:
An indication of whether or not the item is portable.APCB
Portability:
Portable
MRC:
The minimum and maximum amount of absorbed radiation detected per hour.CTJX
Err Default:
Err default
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Extended 0 to 999 sv, 0 to 999 r, dose range; easy-to-read autoranging lcd provides dose, dose rate and stay-time information; a single aa battery lasts more than 750 hours; dose history stores 200 data points; dust and shock resistant; long calibration life; provides does readings with a resolution of less than 0.02 usv, 2 ur; alerts wearer with a loud 75 plus db alarm at 30 cm for noisy environments and big, bright flashing leds; energy response tissue equivalent to porm 25 pct from 55 kev to 6 mev; no fold over up to 100 sv/h; user calibration recommended at least every 2 years; factory calibration not required; datalog interval 6 s to 109 h
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Rugged, lightweight, direct-reading electronic personal dosimeter that provides superior dose monitoring accuracy
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Operating enviroment temperature m28.0 to p60.0 degrees c; humidi type 0 to 95 pct non-condensing; shock resistance passes drop test from 1 m, 39 inch onto concrete; ip rating ip54; built-in continous self-test monitors power supply and g-m tube; abnormal operation indicated on lcd; weight 130 g