Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Pulse Generator
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
23.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
14.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.000 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Free-standing
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
0.5
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
40.0 kilowatts output
MRC:
The length of time it takes the pulse to rise per channel.BHTQ
Pulse Rise Time Per Channel:
100.000 nanoseconds output channel
MRC:
The length of time it takes the trailing edge of the pulse to fall per channel.BHTR
Pulse Decay Time Per Channel:
200.000 nanoseconds output channel
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Positive output channel
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
0.010 kilopulses per second output channel err-100
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
10.000 kilopulses per second output channel err-100
MRC:
The maximum absolute peak value of the pulse per channel.BHTW
Pulse Peak Amplitude Per Channel:
5.000 volts output channel
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
Output channel radio frequency
MRC:
The limits of calbration,expressed in percent.BJBH
Calibrated Tolerance In Percent:
-0.5/+0.5
MRC:
The physical configuration of the output wave.BJBJ
Output Wave Shape:
Pulse, variable width
MRC:
Indicates the type and number of indicator device(s) included.BJBL
Indicator Device Type And Quantity:
4 meter
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
50.0 single voltage
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
60.0 single voltage
MRC:
A designation of the function which is calibrated.BJBS
Calibration Function:
Frequency
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
115.0 single voltage