Part Number PM1

Radiac Calibrator Set

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
pm1
Demil:
No
Shelf Life:
UOM:
NIIN:
013700545

Part Information
Chambers: a3 3/8 in radius, 3.6 vol cc, 0.0 r/nc cal factor; a4 - 3/4 in rad, 30 cc volume, 0.09 r/nc cal; a51-1/8 in radius, 100 cc vol, 0.03 r/nccal; a6 - 2-1/4 in. Rad, 800 cc vol; 0.004 r/nc cal; laser: 1-6 meters/sec velocity; 2 g's acceleration; distance .17-30 meters; elevataion porm 60 deg; electrometer: 200 mv-200 v range; 10 uv-10 mv resolution; power supply: 0-3 kv dc output; thermometer: 0.1 degrees resolution; displays degrees f. Or c.; barometer: 0.5-19 psia, 3.5-130 kpaa

NSN
National Stock Number:
6665-01-370-0545 6665013700545
TXT
Description:
Radiac Calibrator Set
INC
INC
Item Name Code:
00396
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
1 and 1 and 1 and 1 and 1 and 1 and 1 and 1 and 1 and 1
MRC:
The number of components included in the item.AJJW
Component Quantity:
6
MRC:
A listing of those major components which are comprised of a national stock number,an item name,standardized name,or part name,and the number of each.AJKC
Supply Items And Quantities:
R6130-01-174-0653 power supply 1; 6625-01-251-5909 multimeter 1; digitalthermometer 1; dosimeter 1; electronicbarometer 01; cavity ionization chamber 4; coaxial termination 1; laser measurement system 1; electrometer 1
MRC:
The name of the government agency or commercial organization that controls the manufacture of the accessory item.AKVY
Accessory Controlling Agency:
Keithley instruments inc; kitrickmanagement co; ruska instrument co; exradin inc; exradin inc; chesapeake laser systems inc
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Calibrates gamma radiation sources (standards) model 81-10 on site; electrometer used to measure charge accumulated by ionization chamber; barometer and thermometer measure pressure andtemperature at point of measurement; laser measurement system measures distance from radiation source to detector and used to calibrate radiation track system

Similar Radiac Calibrator Sets

« Hazard-detecting Instruments and Apparatus Catalog
Compare Now »
Clear | Hide