Part Number POM-19VC-2

Laboratory Oven

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
pom-19vc-2
Demil:
No
Shelf Life:
UOM:
NIIN:
010232809
NSN
National Stock Number:
6640-01-023-2809 6640010232809
TXT
Description:
Laboratory Oven
INC
INC
Item Name Code:
17096
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
38.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
76.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
33.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
Inside Width:
16.000 inches
MRC:
An inside measurement between specified points of an item,in distinction from height.AFEF
Inside Depth:
17.250 inches
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
W/cabinet stand 1
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
240.000 volts
MRC:
The minimum and maximum operating temperatures at which the item is rated,expressed in degrees celsius.ASQJ
Operating Tempurature Range In Deg Celsius:
+0.0/+200.0
MRC:
The heat source for which the item is designed.AZZH
Heat Source For Which Designed:
Integral
MRC:
The means by which the item is heated.BDWT
Heating Method:
Electrical
MRC:
An indication of whether or not the item is provided with a water jacket.BGXH
Water Jacket:
Not provided
MRC:
The means used to provide circulation.BHGT
Circulation Method:
Mechanical
MRC:
An indication of whether or not an insulated cabinet is provided.BLST
Insulated Cabinet:
Provided
MRC:
The element,compound,or mixture of which the cabinet outer wall is fabricated,excluding any surface treatment.BQMH
Cabinet Outer Wall Material:
Steel
MRC:
The element,compound,or mixture of which the cabinet inner wall is fabricated,excluding any surface treatment.BQMJ
Cabinet Inner Wall Material:
Steel
MRC:
Indicates the type of mount utilized to support the cabinet.BQML
Cabinet Mounting Type:
Stand
MRC:
The number of outer doors included.BQMN
Outer Door Quantity:
1
MRC:
An indication of whether or not a vacuum chamber is included.BQWN
Vacuum Chamber:
Included
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the vacuum chamber.BQWP
Vacuum Chamberlength:
17.250 inches
MRC:
The length of a straight line which passes through the center of the vacuum chamber,and terminates at the inside circumference.BQWQ
Err Default:
Err default
MRC:
An indication of whether or not the vacuum chamber is removable.BQWR
Vacuum Chamber Removability:
Nonremovable
MRC:
The number of alternating current phases.FAAZ
Phase:
Single