Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Film Fixed Resistor
MRC:
A constant that represents the proportionate change in resistance caused by a change in temperature,expressed in parts per million change per degree celsius.AAPE
Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius:
-5.0/+5.0
MRC:
A measure of the opposition to the flow of electrical current.AAPP
Electrical Resistance:
12.100 kilohms
MRC:
The limits of permissible variation in the electrical resistance value of an item from its rated value,expressed in percent.AAPQ
Resistance Tolerance In Percent:
-0.250/+0.250
MRC:
The ambient temperature of the medium surrounding an item at which it can be operated continuously at full rated power,expressed in degrees celsius.AAQF
Ambient Tempurature In Deg Celsius At Full Rated Power:
60.0
MRC:
The ambient temperature at which the power dissipation of an item is operated to zero percent of the full rated power,expressed in degrees celsius.AAQG
Ambient Tempurature In Deg Celsius At Zero Percent Rated Power:
175.0
MRC:
The maximum and minimum temperatures to which the temperature coefficient applies,expressed in degrees celsius.AAQH
Tempurature Range Of Tempurature Coefficient In Deg Celsius:
-55.0/+125.0
MRC:
The means provided to coat,cover,or protect the item.AAQZ
Inclosure Method:
Encapsulated
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Wire lead
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
0.870 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.295 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.320 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.100 inches
MRC:
The maximum amount of electrical energy that can be expended by an item,expressed in watts.AEFB
Power Dissipation Rating In Watts:
0.300 free air
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Terminals one edge
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
09344-ps70044 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)