Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Surface mount analog level detector 20 to 2000 mhz
NSN
National Stock Number:
TXT
Description:
Audio Frequency Detector
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
0.230 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.120 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.230 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0 to 125.0 degrees celsius
MRC:
The minimum and maximum temperatures at which an item can be stored without detrimental effect.AFJQ
Storage Tempurature Range:
-62.0 to 150.0 degrees celsius
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
A designation assigned to the item for purpose of ready identification.AJKH
Identification Designator:
Analog level detector
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Manual
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
20.0 megahertz operating channel and 2000.0 megahertz operating channel
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
22.0 volts output
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
15.0 single voltage
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Wideband, temperature compensated, low vswr, small size, surface mount
MRC:
Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
Special Test Features:
temperature exposure is 260 celsius for 10 seconds
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Wideband analog detector, contains a diode detector and a preci