Part Number QUANTIM16

Surgical Instrument A Sterilizer

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
quantim16
Demil:
No
Shelf Life:
UOM:
NIIN:
015421666

Part Information
Sterilizer surgical instrument and dressing quantim 16

NSN
National Stock Number:
6530-01-542-1666 6530015421666
TXT
Description:
Surgical Instrument A Sterilizer
INC
INC
Item Name Code:
04496
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.AARX
Inside Diameter:
10.000 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
17.300 inches
MRC:
The rated power that an item can safely consume or provide,measured in watts.ABJL
Wattage Rating In Watts:
1500.0
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
16.100 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
18.900 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
A measurement of the longest inside dimension of an item,in distinction from width.ADJU
Inside Length:
13.000 inches
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
110.0 volts
MRC:
The number of individual motors provided.AZCJ
Individual Motor Quantity:
1
MRC:
Indicates the type of current required to operate the motor.AZKJ
Motor Current Type:
Ac
MRC:
The total electrical voltage of the motor,expressed in volts.AZKK
Motor Voltage In Volts:
110.0
MRC:
The means by which the item is heated.BDWT
Heating Method:
Electrical
MRC:
The means provided to close the opening of the item.CPMD
Closure Method:
Autoclave safety door opened by touch of button
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Seamless chamber; holds up to six open instrument trays, three 8x11 instrument cassettes, a pouched instrument rack or various instrument cassettes; microprocessor-controlled cycle times and temps; front fill and drain capabilities for fast draining of the reservoir

Similar Surgical Instrument A Sterilizers

« Hospital Furniture, Equipment, Utensils and Supplies Catalog
Compare Now »
Clear | Hide