Part Number R1570M34-2

Line Electro-mechanical Actuator
Stock Availability  condition code chart

Part number r1570m34-2 is in stock in the following quantities and conditions.

  • OH: 1
  • SV: 1
  • AR: 1

Note: Availability of this item was last updated 10/11/2024 and may have changed since then. Request a quote for up to date pricing and availability.

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
r1570m34-2
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
008045756
NSN
National Stock Number:
1680-00-804-5756 1680008045756
TXT
Description:
Line Electro-mechanical Actuator
INC
INC
Item Name Code:
10957
INC
COM
Compliance:
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Connector
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
2.790 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
3.090 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Any acceptable
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
10000.0 feet
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
1.0
MRC:
A measurement of the longest dimension of the stroke,in distinction from width.AMWL
Stroke Length:
6.000 inches
MRC:
An indication of whether or not a limit switch control is included.AWQN
Limit Switch Control:
Included
MRC:
The means used to reset the thermal protector.AWQP
Thermal Protector Reset Method:
Automatic
MRC:
An indication of whether or not a manual override is included.AWQR
Manual Override:
Not included
MRC:
The tension stress applied to the item under load conditions.AWTA
Tension Load Rating:
1000.0 pounds static err-100
MRC:
The tension stress applied to the item under load conditions.AWTA
Tension Load Rating:
50.0 pounds operating err-100
MRC:
The compression stress applied to the item under load conditions.AWTC
Compression Load Rating:
200.0 pascal grams static
MRC:
The compression stress applied to the item under load conditions.AWTC
Compression Load Rating:
50.0 pascal grams operating
MRC:
The rate of linear travel per unit of time.AWTE
Rated Stroke Velocity:
10.000 inches per second
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
26.0