Part Number R1596-4004

Nonind Wire Wound Fixed Resistor

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
r1596-4004
Demil:
No
Shelf Life:
UOM:
NIIN:
000717481
NSN
National Stock Number:
5905-00-071-7481 5905000717481
TXT
Description:
Nonind Wire Wound Fixed Resistor
INC
INC
Item Name Code:
37404
MRC:
A constant that represents the proportionate change in resistance caused by a change in temperature,expressed in parts per million change per degree celsius.AAPE
Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius:
-7.0/+10.3
MRC:
A measure of the opposition to the flow of electrical current.AAPP
Electrical Resistance:
10.000 kilohms
MRC:
The limits of permissible variation in the electrical resistance value of an item from its rated value,expressed in percent.AAPQ
Resistance Tolerance In Percent:
-0.020/+0.020
MRC:
The ambient temperature of the medium surrounding an item at which it can be operated continuously at full rated power,expressed in degrees celsius.AAQF
Ambient Tempurature In Deg Celsius At Full Rated Power:
125.0
MRC:
The ambient temperature at which the power dissipation of an item is operated to zero percent of the full rated power,expressed in degrees celsius.AAQG
Ambient Tempurature In Deg Celsius At Zero Percent Rated Power:
145.0
MRC:
The maximum and minimum temperatures to which the temperature coefficient applies,expressed in degrees celsius.AAQH
Tempurature Range Of Tempurature Coefficient In Deg Celsius:
-65.0/+145.0
MRC:
The means provided to coat,cover,or protect the item.AAQZ
Inclosure Method:
Encapsulated
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Wire lead
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Established
MRC:
The rate of failure determined under specified conditions to establish the reliability of an item,expressed in percent.AARH
Reliability Failure Rate Level In Percent:
0.010
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
Between 1.875 inches and 2.125 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
Between 0.235 inches and 0.265 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 0.735 inches and 0.765 inches
MRC:
The maximum amount of electrical energy that can be expended by an item,expressed in watts.AEFB
Power Dissipation Rating In Watts:
0.250 free air
MRC:
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.CBME
Cubic Measure (non-core):
0.042 cubic inches
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Terminal surfaces gold
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material (non-core):
Gold
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Axial terminal each end
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
06481-900612 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)