Part Number RADCAL9010

Radiac Set

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
radcal9010
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
015157846

Part Information
Dfunctions auto zero; dose rate; maximum dose rate; dose; auto dose; pulsed, cine; lcd display test lcd display verification; battery test checks battery voltage; chamber voltage test checks bias voltage

NSN
National Stock Number:
6665-01-515-7846 6665015157846
TXT
Description:
Radiac Set
INC
INC
Item Name Code:
07331
INC
COM
Compliance:
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
X-ray service, x-ray qa and compliance, x-ray acceptance testing, industrial applications, medical and health physics, therapy qa, secondary standards, nuclear applications, radiography, fluoroscopy, angiography, mammography; image intensifier; pulsed x-ray; cine; ct; dental; 137cs; 60co irradiator measurements; survey meter calibration; industrial x-ray, cables up to 300 feet; very low dose rates and very high dose rate applications, up to 107r/hr with special modification
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Included
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Visual
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
X-rays detects
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Multipurpose dosemeters
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Porm 4 pct of reading, porm 1 digit, porm 2 times resolution; repeatability porm 1 pct of reading, porm 1 digit, porm 2 times resolution; auto temperature accuracy 2 pct; auto pressure accuracy 0.2 pct, plus 2 pct of reference pressure-ambient, optional specify opt-p; analog capture 0-5 v, 10khz, 12 bit analog to digital signal capture, 100 usec and 1.25 mv resolution over1 sec; playback to analog output; data available at the rs-232 port or anlaog out; timing 5 ms to 6.5 sec with 100usec resolution with porm 0.05 pct accuracy; exclusive of non-invasive detector; infrared remote allows full control from up to 10 m away, will go through lead glass