Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
rl270b2
Demil:
No
Shelf Life:
UOM:
NIIN:
005780291
NSN
National Stock Number:
5905-00-578-0291 5905005780291
TXT
Description:
Pre Wire Wound Variable Resistor
INC
INC
Item Name Code:
37408
MRC:
The number of individual elements.AAPN
Section Quantity:
4
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Cylindrical studs mounted
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
2.000 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.249 inches
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.750 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.750 inches
MRC:
None.AEDE
Mounting Hole/stud Circle Diameter:
1.250 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.AEDX
Shaft Style:
Round
MRC:
Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
Actuator Type:
Double ended shaft
MRC:
The length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread.AJYN
Screw Thread Diameter:
0.164 inches
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.AJYP
Screw Thread Series Designator:
Unc
MRC:
The number of screw threads on the item per linear inch measured on a line parallel to the thread axis,including incomplete threads.AJYQ
Screw Thready Qty Per Inch (tpi):
32.0
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
3
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Radially positioned over more than half the circumference
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded hole
MRC:
A measure of the opposition to the flow of direct or alternating current per section.CQCC
Electrical Resistance Per Section:
29.218 percent, rated amperes c and better industrial clears
MRC:
A measure of the opposition to the flow of direct or alternating current per section.CQCC
Electrical Resistance Per Section:
490.0 percent, rated amperes c and better finish
MRC:
A measure of the opposition to the flow of direct or alternating current per section.CQCC
Electrical Resistance Per Section:
490.0 percent, rated amperes c and better select
MRC:
A measure of the opposition to the flow of direct or alternating current per section.CQCC
Electrical Resistance Per Section:
490.0 percent, rated amperes c and better v.G. Stepping
MRC:
The location per section,in degrees,of effective electrical rotation between the counterclockwise terminal of a resistor and each tap terminal.CQCH
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
221.0 2nd section
MRC:
The location per section,in degrees,of effective electrical rotation between the counterclockwise terminal of a resistor and each tap terminal.CQCH
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
236.0 1st section
MRC:
The location per section,in degrees,of effective electrical rotation between the counterclockwise terminal of a resistor and each tap terminal.CQCH
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
236.0 3rd section
MRC:
The location per section,in degrees,of effective electrical rotation between the counterclockwise terminal of a resistor and each tap terminal.CQCH
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
236.0 4th section
MRC:
The permissible range per section by which the actual value of resistance or voltage at any specified point may deviate from the theoretical value for the linear or nonlinear function,expressed as a minus and plus percent.CQFL
Function Conformity Tolerance Per Section:
-0.10/+0.10 1st section
MRC:
The permissible range per section by which the actual value of resistance or voltage at any specified point may deviate from the theoretical value for the linear or nonlinear function,expressed as a minus and plus percent.CQFL
Function Conformity Tolerance Per Section:
-0.10/+0.10 3rd section
MRC:
The permissible range per section by which the actual value of resistance or voltage at any specified point may deviate from the theoretical value for the linear or nonlinear function,expressed as a minus and plus percent.CQFL
Function Conformity Tolerance Per Section:
-0.10/+0.10 4th section
MRC:
The permissible range per section by which the actual value of resistance or voltage at any specified point may deviate from the theoretical value for the linear or nonlinear function,expressed as a minus and plus percent.CQFL
Function Conformity Tolerance Per Section:
-0.15/+0.15 2nd section
MRC:
A constant that represents the proportionate change in resistance caused by a change in temperature per section,expressed in parts per million per degree celsius.CRFJ
Tempurature Coefficient Of Resistance Per Section In Ppm Per Deg Celsius:
-20.0/+20.0 all sections
MRC:
The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
Power Dissipation Rating Per Section In Watts:
3.0 free air single section
MRC:
The fidelity of the relationship between the actual function characteristics and the theoretical function per section.CRGM
Function Conformity Per Section:
All sections independent linearity
MRC:
The number of fixed terminals at points between the end terminals that provide connection to the intermediate values of the total value per section.CRJS
Fixed Tap Quantity Per Section:
1 all sections
MRC:
The limits of permissible variation from the rated value of the location of a tap per section.CRKS
Tap Location Tolerance Per Section:
-0.5/+0.5 degrees angular rotation all sections
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-1.0/+1.0 2nd section
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-1.0/+1.0 3rd section
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-1.0/+1.0 4th section
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-5.0/+5.0 1st section
MRC:
The specified mathematical relation per section between the terminal resistance,or output ratio,and the rotation of the actuator.CSBX
Function Characteristic Per Section:
All sections linear
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
16 solder stud