Part Number S3801-3120145

Centrifugal Fan Assembly

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
s3801-3120145
Demil:
No
Shelf Life:
UOM:
NIIN:
002401848
NSN
National Stock Number:
4140-00-240-1848 4140002401848
TXT
Description:
Centrifugal Fan Assembly
INC
INC
Item Name Code:
04254
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
The different speeds at which the item may be operated.ABBB
Speed Adjustments:
Single speed
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
53.563 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
55.000 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Dripproof
MRC:
The temperature of the medium surrounding an item at which it can be operated continuously at full rated power.AEHY
Ambient Tempurature At Full Rated Power:
65.0 degrees celsius
MRC:
The speed of the drive shaft required to produce the rated capacity of an item,expressed in revolutions per minute.AEQC
Operating Speed At Rated Capacity In Rpm:
1750.0
MRC:
None.AJLU
Outlet Inside Width:
16.000 inches
MRC:
None.AJLV
Outlet Inside Height:
36.000 inches
MRC:
The static pressure measured at the air flow rate specified.AJLY
Static Pressure At Specificationified Air Flow Rate:
5.3 inches of water
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Direct
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The direction of rotation for which the item is designed.AYSY
Rotation Direction For Which Designed:
Counterclockwise
MRC:
The rated capacity of air flow moved through the item.CQKX
Air Flow Rate:
19000.000 cubic feet per minute
MRC:
Indicates the location of the outlet on the item.CRWJ
Outlet Location:
Top
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
220.0 ac
MRC:
The rated power of the prime mover.CSYL
Prime Mover Power Rating:
30.000 horsepower
MRC:
Indicates the type of bearing/s/ provided on the prime mover drive shaft.CWLY
Prime Mover Drive Shaft Bearing Type:
Ball
MRC:
The direction in which the item discharges during operation.CXCB
Discharge Direction:
Horizontal
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
60.626 inches
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel blade
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel housing
MRC:
A numeric value which represents a positive whole value without regard to any unit of measure.NMBR
Quantity:
1
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Zinc blade
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Zinc housing inside
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Zinc housing outside
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Fixed, rectangular outlets
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
As differentiated by cw rotation as viewed facing the driving side

Similar Centrifugal Fan Assemblies

« Fans, Air Circulators and Blower Equipment Catalog
Compare Now »
Clear | Hide