Part Information
Centrifuge lab 15ml tube 115v 60hz ac/dc

NSN
National Stock Number:
6640-00-494-3822 6640004943822
TXT
Description:
Laboratory Centrifuge
INC
INC
Item Name Code:
17093
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.AARX
Inside Diameter:
13.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
12.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac/dc
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
13.500 inches
MRC:
A linear measurement from the surface to a specified inner point on an item,in distinction from height.AEJZ
Depth:
6.000 inches
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
4 rubber cushions for 15 ml metal shields
MRC:
The means used to operate the item.APHE
Operation Method:
Electric
MRC:
Indicates the type of separation unit provided.ATPH
Separation Unit Type:
Trunnion
MRC:
The number of places provided in the head.ATPJ
Head Place Quantity:
4
MRC:
Designates the size of the container that each place will accommodate.ATPM
Place Container Size:
15 ml tube
MRC:
An indication of whether or not a safety cap is included.ATPQ
Safety Cap:
Not included
MRC:
The maximum speed at which the item is designed to operate,expressed in revolutions per minute.ATPR
Maximum Speed Rating In Rpm:
4290.0
MRC:
An indication of whether or not a guard bowl is included.ATPT
Guard Bowl:
Included
MRC:
Controls furnished which are not specified elsewhere.ATPW
Furnished Controls:
Rheostat
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Damon/iec catalog no. 428 clinical centrifuge w/catalog nos. 215 (head), 310 (rings) and 356 (shields and cushions); clay adams catalog no. 0031 safeguard centrifuge w/catalog nos. 0036 (head with rings) and 0901 (shields and cushions)

Similar Laboratory Centrifuges

« Laboratory Equipment and Supplies Catalog
  • 570
    NSN: 6640-00-494-3825
  • 571
    NSN: 6640-00-494-3826
  • 667
    NSN: 6640-00-494-3828
  • 303
    NSN: 6640-00-494-3830
  • NNNC00435
    NSN: 6640-00-494-3838
Compare Now »
Clear | Hide