Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Sixth grouping arrangement eleventh and twelfth conductor through twelfth grouping arrangement twenth-third and twenty-fourth conductor
NSN
National Stock Number:
TXT
Description:
Electrical Power Cable
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-40.0 degrees celsius and 85.0 degrees celsius
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
1.315 inches
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
24
MRC:
The specification, standard, drawing, or similar instrument that specifies the individual color coding under which the item is identified by an alphabetic and/or numeric reference number.includes the commercial and government entity (cage) code of the entity controlling the instrument.AWXS
Color Coding Document:
Fmc-13035 specification
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
7 all conductors
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded all conductors
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
18 awg all conductors
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
26 all conductors
MRC:
The arrangement and number of arrangements of the conductors.CXDQ
Conductor Arrangement And Quantity:
12 twisted pair
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
Fifth conductor third group and sixth conductor third group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
First conductor first group and second conductor first group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
Ninth conductor fifth group and tenth conductor fifth group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
Seventh conductor fourth group and eighth conductor fourth group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
Third conductor second group and fourth conductor second group
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
600.0 root mean square (rms) operating voltage all conductors
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black 1st position jacket cable
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper core conductor all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyethylene terephthalate 1st position primary insulation all conductors
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Astm b3 assn standard single material response core conductor all conductors