Part Number SF-0603F100

Inclosed Link Fuse

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
sf-0603f100
Demil:
Shelf Life:
UOM:
NIIN:
016252866

Part Information
Bourns sf-0603f series - fast acting surface mtg fuse

NSN
National Stock Number:
5920-01-625-2866 5920016252866
TXT
Description:
Inclosed Link Fuse
INC
INC
Item Name Code:
00249
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular plug-in
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 1.5 millimeters and 1.7 millimeters
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Between 0.7 millimeters and 0.9 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 0.44 millimeters and 0.46 millimeters
MRC:
The maximum direct current,or root mean square current at rated frequency,that an item will carry continuously.AEBJ
Continuous Current Rating In Amps:
50.0
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
32.0 dc
MRC:
Indicates the type of over-current conditions that an item is designed to withstand indicated by the speed of circuit interruption.AFXF
Circuit Over-current Interruption Type:
Time delay
MRC:
The means in which the item signals the interruption of a circuit.AFXH
Interruption Indicator Method:
No visual indication
MRC:
The time elapsing before circuit interruption of an item operated at a specified percent of its normal current rating,expressed in seconds.CQPB
Circuit Over-current Interruption Delay Time In Seconds:
60.0 200 pct of current rating
MRC:
The maximum rated current at which the item will interrupt or short circuit,expressed in amperes.CSQN
Short-circuit/interrupt Current Rating In Amps:
50.0
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Ambient operating temp is -40 degrees c to 105 degrees c; item is flat on both sides, no pins are shown; item is rated at 1 amp; item is rohs compliant and halogen free

Similar Inclosed Link Fuses

« Fuses, Arrestors, Absorbers and Protectors Catalog
Compare Now »
Clear | Hide