Part Number SK5320-3000

Signal Data Converter

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
sk5320-3000
Demil:
No
Shelf Life:
UOM:
NIIN:
005030669
NSN
National Stock Number:
6660-00-503-0669 6660005030669
TXT
Description:
Signal Data Converter
INC
INC
Item Name Code:
00441
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
10.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
10.000 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-40.0/+150.0 degrees fahrenheit
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
A designation assigned to the item for purpose of ready identification.AJKH
Identification Designator:
Cv146tmq5-80058
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
10000.0 feet
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Rack
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
10.0 hertz input channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
220.0 hertz input channel err-100
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
100.000 kilohms input channel err-100
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
5.000 kilohms output channel err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
1st input channel audio frequency err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
2nd input channel servo err-100
MRC:
The maximum time an item will continuously run,expressed in hours.BJBM
Maximum Continuous Operating Time In Hours:
1000.0
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
50.0 single voltage
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
65.0 single voltage
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
300.0 3rd voltage err-100
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
-12.5 1st voltage err-100
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
-25.0 2nd voltage err-100
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
106.0 single voltage
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
125.0 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-milr10882 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Radiosonde recorder

Similar Signal Data Converters

« Meteorological Instruments and Apparatus Catalog
Compare Now »
Clear | Hide