Part Number SL-8306-219-C033

Motor Starter

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
sl-8306-219-c033
Demil:
No
Shelf Life:
UOM:
NIIN:
012522330
NSN
National Stock Number:
6110-01-252-2330 6110012522330
TXT
Description:
Motor Starter
INC
INC
Item Name Code:
00905
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
16.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
12.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
440.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Manual
MRC:
Indicates the performance capability of the item or component.AGLD
Performance Type:
Manual
MRC:
The number of fuses the item is designed to accommodate /including spares/.AGUE
Fuse Accommodation Quantity:
2 and 2
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
An indication of the rated horsepower of the item.ANCY
Horsepower Rating:
15.000
MRC:
The voltage required to actuate the item.ANDE
Actuator Voltage:
110.0 ac
MRC:
The value of current for which the fuse is rated,expressed in amperes.ANDG
Fuse Current Rating In Amps:
1.0 and 2.0
MRC:
Indicates the type of load for which the item is protected.ANDW
Load Protection Type:
Overload and overcurrent
MRC:
An indication of whether or not the item is designed in conformance with the national electrical manufacturers association (nema) standards.ANQC
National Electrical Manufacturers Association Standards Design:
Not designed per nema std
MRC:
The ampere size designation for special design type items which are rated in ampere size rather than horsepower.ANRH
Amp Size Rating:
18.7
MRC:
Indicates the type of control.AQZF
Control Type:
Local
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Circuit protection fuse
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0

Similar Motor Starters

« Electrical Control Equipment Catalog
Compare Now »
Clear | Hide