Part Number SM-C-5362688-2

Radio Frequency Interfere Filter

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
sm-c-5362688-2
Demil:
No
Shelf Life:
UOM:
NIIN:
001633912
NSN
National Stock Number:
5915-00-163-3912 5915001633912
TXT
Description:
Radio Frequency Interfere Filter
INC
INC
Item Name Code:
00765
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.355 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.550 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
0.375 inches
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
+10.0/+2000.0
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
+10.0 to 2000.0
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
50.0 ohms blank
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
50.0 ohms blank
MRC:
The cycles per second /hertz/ of the power line alternating current.AHBB
Power Line Frequency Rating Per Function In Hertz:
420.0 blank
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
5.0 blank
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance blank
MRC:
The specified points in the frequency spectrum at which insertion losses (as a function of frequency) under full load are measured,expressed in megahertz.AHCJ
Full Load Insertion Loss Frequencies In Megahertz:
0.3 and 1.0 and 10.0 and 100.0 and 1000.0 and 10000.0
MRC:
The least permissible values for attenuation of spurious or unwanted signals at designated points in the frequency spectrum,expressed in decibels.AHCK
Full Load Minimum Insertion Loss At Specificationified Frequency In Decibels:
10.0 and 40.0 and 80.0 and 80.0 and 80.0 and 80.0
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.AKEJ
Mounting Facility Screw Thread Series Designator:
Unf
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 threaded bushing
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
1 tab, solder lug input 1st function
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
1 tab, solder lug output 2nd function
MRC:
The level of electrical potential and type of current,per function,for which the item is designed.CQGC
Operating Voltage Rating And Type Per Function:
115.0 volts ac blank and 185.0 volts dc blank
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.250 inches
MRC:
The maximum direct current voltage that the insulating material/s/ of the item will withstand without resulting in disruptive discharge or deterioration.CRDC
Maximum Dielectric Withstanding Dc Voltage:
370.0 volts at sea level
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Round terminal/terminals on opposite surfaces

Similar Radio Frequency Interfere Filters

« Filters and Networks Catalog
Compare Now »
Clear | Hide