Part Number SM-D-209752-5

Control Transformer Synchro
Stock Availability  condition code chart

Part number sm-d-209752-5 is in stock in the following quantities and conditions.

  • NS: 39
  • OH: 1
  • AR: 2
  • NE: 1

Note: Availability of this item was last updated 02/09/2022 and may have changed since then. Request a quote for up to date pricing and availability.

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
sm-d-209752-5
Demil:
No
Shelf Life:
UOM:
NIIN:
006440120
NSN
National Stock Number:
5990-00-644-0120 5990006440120
TXT
Description:
Control Transformer Synchro
INC
INC
Item Name Code:
15289
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Aluminum
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Standard round d
MRC:
The length of a straight line which passes through the center of a shoulder,and terminates at the circumference.AAVH
Shoulder Diameter:
Between 1.9890 inches and 1.9900 inches
MRC:
The length of a straight line which passes through the center of that portion used to guide the item and terminates at the circumference.AAVL
Pilot Diameter:
Between 0.5900 inches and 0.6000 inches
MRC:
None.AAZW
Second Shoulder Diameter:
Between 1.9985 inches and 1.9995 inches
MRC:
None.AAZX
Second Shoulder Length:
0.1700 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 4.2430 inches and 4.2940 inches
MRC:
The length of a straight line which passes through the center of a flange,and terminates at the circumference.ABKK
Flange Diameter:
Between 2.2490 inches and 2.2500 inches
MRC:
A measurement of the smallest dimension of a flange,in distinction from length or width.ABKU
Flange Thickness:
0.2500 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
1.9900 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.2402 inches single shaft and 0.2405 inches single shaft
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.6930 inches single shaft and 0.7190 inches single shaft
MRC:
An alpha and/or numeric designation indicating the size by which the body is identified.AJSL
Body Size:
23
MRC:
The value of the primary excitation voltage for which the stator is rated,expressed in volts.AJSN
Stator Input Voltage Rating In Volts:
90.0
MRC:
The value of the primary excitation current for which the stator is rated,with rotor /secondary/ circuit open.AJSP
Stator Input Current Rating:
6.0 milliamperes
MRC:
The value of the primary /electrical/ excitation power for which the stator is rated.AJSQ
Stator Input Electrical Power Rating:
240.0 milliwatts
MRC:
The cycles per second /hertz/ of the alternating current.AJSS
Frequency In Hertz:
400.0
MRC:
The maximum voltage,without harmonics,induced in the secondary circuit at the null angle rotor position,expressed in millivolts per volt.AJVG
Maximum Fundamental Null Voltage In Millivolts Per Volt:
30.00 output
MRC:
The maximum voltage,including harmonics,induced in the secondary circuit at the null angle rotor position,expressed in millivolts per volt.AJVH
Maximum Total Null Voltage Output In Millivolts Per Volt:
60.00
MRC:
The limits of permissible deviation in angular arc error from electrical zero,expressed in minutes.AJVL
Electrical Error Angular Range In Minutes:
-6.0/+6.0
MRC:
The amount of rotary force that must be applied to the actuator to cause rotation,at minus 55 degrees celsius.AJVS
Actuator Friction Torque At Minus 55 Deg Celsius:
0.50 inch-ounces
MRC:
The amount of rotary force that must be applied to the actuator to cause rotation,at plus 25 degrees celsius.AJVT
Actuator Friction Torque At Plus 25 Deg Celsius:
0.20 inch-ounces
MRC:
A measurement of the longest dimension of a pilot,in distinction from width.AJWQ
Pilot Length:
0.0460 inches
MRC:
None.AJWR
Shoulder Length:
0.2500 inches
MRC:
None.AJWV
Aft Of First Flange Diameter:
Between 1.9985 inches and 1.9995 inches
MRC:
None.AJWX
Mounting Surface To Terminal End Distance:
Between 3.4350 inches and 3.4450 inches
MRC:
A designation distinguishing one group of shaft thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.AJYY
Shaft Thread Series Designator:
Unf single shaft
MRC:
The direction of the shaft thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AKAF
Shaft Thread Direction:
Right-hand single shaft
MRC:
A numeric-alpha designator indicating the ptich diameter tolerance,and an external or internal shaft thread.AKAN
Shaft Thread Class:
3a
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
Rear
MRC:
A measurement of the extent of the shaft threads measured on a line parallel to the longitudinal axis.CQWQ
Shaft Thread Length:
0.3100 inches single shaft
MRC:
Indicates the type of shaft included on the item.CRSJ
Shaft Type:
Round, threaded single shaft
MRC:
The ratio of the output voltage to the input voltage at maximum coupling.CSJY
Transformation Ratio:
0.735 rotor to stator
MRC:
The length of a straight line passing through the center of the shaft threaded portion,with terminated points at the circumference.CWBH
Shaft Thread Size:
0.250 inches single shaft
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-s-16892 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
7 screw