Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Radio Frequency Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.530 inches
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
50 single component 2nd secondary
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
50 single component 1st secondary
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
87 single component 3rd secondary
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
10 single component single primary
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.200 inches single group and 0.206 inches single group
MRC:
The means by which a protective metal screen,plate,or inclosure is placed around or between the windings of an item to prevent electrostatic or magnetic coupling.ACZX
Winding Shielding Method:
Grounded to inclosure and brought out to terminal single component
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.248 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
1.750 inches
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
2.150 inches single mounting facility single center group
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
2 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Winding turns single component single primary
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Winding turns single component all secondary
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 3 secondary single component
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Color coded lead
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.00631 inches american wire gage single component all secondary
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.00631 inches american wire gage single component single primary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
10 wire lead