Part Information
Support the patriot missile system
NSN
National Stock Number:
TXT
Description:
Telegraph-telephone Si Converter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
17.250 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
8.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
12.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.0 hertz
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz
MRC:
The name assigned to the item by the joint electronics type designation system.AKWA
Joint Electronics Type Designation System Item Name:
Converter, telephone signal
MRC:
The type number assigned to the item by the joint electronics type designation system.AKWB
Joint Electronics Type Designation System Item Type Number:
Cv-1548/g
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
Indicates the type of signalling the item will perform.ANEQ
Signal Type:
Ring down and supervisory
MRC:
Indicates the type of switchboard side current,whether alternating or direct.BGGY
Switchboard Side Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which the switchboard received signal is rated.BGHB
Err Default:
Err default
MRC:
The number of complete cyclic changes,per unit of time,for which the switchboard received signal is rated.BGHB
Received Switchboard Signal Frequency Rating:
20.0 hertz
MRC:
The number of complete cyclic changes,per unit of time,for which the switchboard transmitted signal is rated.BGHC
Err Default:
Err default
MRC:
The number of complete cyclic changes,per unit of time,for which the switchboard transmitted signal is rated.BGHC
Transmitted Switchboard Signal Frequency Rating:
20.0 hertz
MRC:
The value,or range of values,of direct current potential for which the received signal is rated.BGHD
Err Default:
Err default
MRC:
The value,or range of values,of direct current potential for which the received signal is rated.BGHD
Received Signal Dc Voltage Rating:
24.0 volts
MRC:
The value,or range of values,of direct current potential for which the transmitted signal is rated.BGHF
Err Default:
Err default
MRC:
The value,or range of values,of direct current potential for which the transmitted signal is rated.BGHF
Transmitted Signal Dc Voltage Rating:
32.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which the transmitted line signal is rated.BGHG
Transmitted Line Signal Frequency Rating:
1.6 kilohertz
MRC:
The number of complete cyclic changes,per unit of time,for which the received line signal is rated.BGHH
Received Line Signal Frequency Rating:
1.6 kilohertz
MRC:
The number of communication circuits provided.BGHJ
Communication Circuit Quantity:
12
MRC:
The number of alternating current phases.FAAZ
Phase:
Single