Part Information
Frequency rating: p47.500/p420.000; modulation degree: 0 to 40 kc deviation
NSN
National Stock Number:
TXT
Description:
Signal Generator
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Bench
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
13.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
12.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
18.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Aluminum
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.ADTY
Case Surface Treatment:
Enameled
MRC:
The range of complete cyclic changes,per unit of time,for which an item is rated.AFGQ
Frequency Range Rating:
+18.000/+80.000 megahertz
MRC:
The name assigned to the item by the joint electronics type designation system.AKWA
Joint Electronics Type Designation System Item Name:
Generator, signal
MRC:
The type number assigned to the item by the joint electronics type designation system.AKWB
Joint Electronics Type Designation System Item Type Number:
Sg-297/urm-103
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The total opposition (resistive and reactive) presented by the item to an alternating current load.AMNE
Output Impedance Rating:
50.0 ohms
MRC:
The number of specified ranges of frequencies or wavelengths operating between two stated limits.ANLC
Frequency Band Quantity:
4
MRC:
The degree of conformity of a measurement to a standard or true value for which the calibration is rated.BDHW
Calibration Accuracy Rating:
Porm 0.185 pct accuracy of calibration
MRC:
An indication of whether or not a crystal controlled feature is provided.BHFY
Crystal Controlled Feature:
Not provided
MRC:
An indication of the calibrated signal range that is output by the item.BHFZ
Calibrated Signal Output Range:
0.05 uv to 0.5 v, calibrated output
MRC:
An indication of the maximum signal output transmitted by the item.BHGB
Maximum Signal Output:
Max output specified in bhfz
MRC:
The number of alternating current phases.FAAZ
Phase:
Single