Part Number SP6-MB-PHL-C-4X

Electromagnetic Fluid Flow Meter

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
sp6-mb-phl-c-4x
Demil:
Shelf Life:
UOM:
NIIN:
016533538

Part Information
Meter, flow rate indicator

NSN
National Stock Number:
6680-01-653-3538 6680016533538
TXT
Description:
Electromagnetic Fluid Flow Meter
INC
INC
Item Name Code:
67476
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Steel, stainless
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Liquid and gas
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Drilled flange
MRC:
The number of inlet bolt holes on the item.ACRL
Inlet Bolt Hole Quantity:
8
MRC:
The length of a straight line which passes through the center of an inlet bolt hole,and terminates at the circumference.ACRM
Inlet Bolt Hole Diameter:
0.875 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Electromagnetic
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
R21fmspa-fs00
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Direct mount
MRC:
The minimum and maximum numeric values representing the measurement coverage of a scale.ANSZ
Scale Measurement Range:
+125.0 to 2900.0
MRC:
The physical configuration of the inlet flange.ARNL
Inlet Flange Shape:
Round
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Drilled flange
MRC:
The physical configuration of the outlet flange.ARTL
Outlet Flange Shape:
Round
MRC:
The smallest numeric figure the item will register.AXEA
Smallest Increment Indicated:
0.35
MRC:
Indicates the location for which the item is designed to be installed.AYNY
Installation Location:
Any acceptable
MRC:
An indication of whether or not the item is provided with a straightening vane/s/.BHCF
Straightening Vane:
Provided
MRC:
An indication of whether or not the item is provided with a reset feature.BHCH
Reset Feature:
Not provided
MRC:
The length of a straight line which passes through the center of an inlet flange,and terminates at the circumference.BHCK
Inlet Flange Diameter:
11.0 inches
MRC:
The length of a straight line which passes through the center of an outlet flange,and terminates at the circumference.BHCN
Outlet Flange Diameter:
11.0 inches
MRC:
The number of outlet bolt hole(s) on the item.BHCT
Outlet Bolt Hole Quantity:
8
MRC:
The length of a straight line which passes through the center of an outlet bolt hole,and terminates at the circumference.BHCW
Outlet Bolt Hole Diameter:
0.875 inches

Similar Electromagnetic Fluid Flow Meters

« Liquid and Gas Flow, Liquid Level and Mechanical Motion Measuring Instruments Catalog
Compare Now »
Clear | Hide