Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
This part for use with brushless excite (primarily on generators rated 150 kw or less)
NSN
National Stock Number:
TXT
Description:
Voltage Regulator
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
11.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
8.410 inches
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.265 inches
MRC:
The center to center distance between mounting holes.ABTH
Center To Center Distance Between Mounting Holes:
5.000 inches and 10.810 inches
MRC:
The number of mounting holes provided.ABTJ
Mounting Hole Quantity:
4
MRC:
The means of attaching the item.ACUN
Mounting Method:
Threaded hole or unthreaded hole
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-67.0/+150.0 degrees fahrenheit
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
B-1b air conditioner
MRC:
The means used for regulating the item.AMZD
Regulation Method:
Electronic
MRC:
Indicates the type of electronic device used for regulating the item.ANAD
Electronic Device Type:
Transistor
MRC:
The regulated value/s/ of the item,expressed in percent.ANBD
Regulation Percent:
0.50
MRC:
The time required for the item to recover.ANBE
Recovery Time:
0.017 seconds
MRC:
Indicates the type of input current whether alternating,direct,or both.ANPJ
Input Current Type:
Ac
MRC:
The input voltage rating at which the item is designed to operate,expressed in volts.ANPK
Input Voltage Rating In Volts:
120.0
MRC:
The cycles per second /hertz/ of the input alternating current.ANPL
Input Frequency Rating In Hertz:
Between 50.0 and 60.0
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single
MRC:
Indicates the type of output current whether alternating,direct,or both.ANPN
Output Current Type:
Dc
MRC:
The output voltage rating at which the item is designed to operate,expressed in volts.ANPP
Output Voltage Rating In Volts:
63.0
MRC:
The total electrical output current.ANPQ
Output Current Rating:
7.0 amperes
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Ventilated