Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Output voltage configurable to 220, 225, 230, or 240 output voltage
NSN
National Stock Number:
TXT
Description:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
26.200 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
17.300 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
9.000 inches
MRC:
The number of batteries required for operation.AEXR
Battery Quantity:
2
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
10000.0 feet
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Floor
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
230.0 ac pounds per hour wet single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
230.0 dc volts multiple power outputs w/identical ratings
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz single operating power rqmt and 60.0 hertz single operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.1/+40.0 degrees celsius
MRC:
The rated output power that an item can safely consume or provide,measured in watts.BGQR
Output Wattage Rating:
3.750 kilowatts multiple power outputs w/identical ratings
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
8 multiple power outputs w/identical ratings
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Connector, receptacle multiple power outputs w/identical ratings
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Wire lead single operating power rqmt
MRC:
An indication of whether or not the battery is rechargeable and the type of battery.CWHY
Battery Feature And Type:
Rechargeable lead acid cell
MRC:
Indicates the location of the battery.CWJF
Battery Location:
Internal
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Single fan
MRC:
The time required to charge a battery(ies) to its rated capacity after a period of discharge.CWWB
Battery Recovery Time:
6.0
MRC:
The emergency operating time a battery power supply can deliver full rated output voltage/current before the output drops below a specified value.CXMX
Battery Power Supply Emergency Operating Time:
18.5