Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Furnished w/bulb holder bracket
NSN
National Stock Number:
TXT
Description:
Thermostatic Switch
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.625 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.000 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
2.500 inches
MRC:
A measurement of the longest dimension of a capillary tube.AEVT
Capillary Tube Length:
240.000 inches
MRC:
A measurement of the longest dimension of a bulb.AEVU
Bulb Length:
4.000 inches
MRC:
The length of a straight line which passes through the center of the bulb,and terminates at the circumference.AEVV
Bulb Diameter:
0.500 inches
MRC:
The longest distance between mounting centers parallel to the horizontal plane.AFDS
Longest Horizontal Distance Between Mounting Centers:
1.188 inches
MRC:
The shortest distance between mounting centers parallel to the horizontal plane.AFDT
Shortest Horizontal Distance Between Mounting Centers:
0.594 inches
MRC:
The longest distance between mounting centers parallel to the vertical plane.AFDV
Longest Vertical Distance Between Mounting Centers:
4.188 inches
MRC:
Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.AKBY
Tempurature Sensing Element Type:
Capillary tube-bulb
MRC:
The means of attaching the item.AXGY
Mounting Method:
Surface
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Electrical access port
MRC:
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
Contact Action Stimulus:
Decrease
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Isosceles triangle
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, double throw, both positions maintained
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Tab w/screw
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
5.1 amperes resistive load single voltage
MRC:
The adjustability of the contact.CTYC
Contact Adjustability:
Deactuation point not adjustable and actuation point adjustable
MRC:
The minimum and maximum limits to which the contact(s) may be adjusted.CTYM
Contact Adjustment Range:
+0.00/+100.00 actuation point degrees fahrenheit
MRC:
Indicates the type of device provided for manual adjustment of the contact(s).CTYS
Contact Adjustment Type:
External actuation point knob with scale
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
240.0 ac at sea level single voltage
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 single voltage
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Gas or liquid