Part Number TDBH120AL

Electromagnetic Relay

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
tdbh120al
Demil:
No
Shelf Life:
UOM:
NIIN:
015189659
NSN
National Stock Number:
5945-01-518-9659 5945015189659
TXT
Description:
Electromagnetic Relay
INC
INC
Item Name Code:
32512
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.200 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.800 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.400 inches
MRC:
The cycles per second /hertz/ of the alternating current.AJSS
Frequency In Hertz:
Between 50.0 and 60.0
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
2
MRC:
The number of coils included on the item.APCN
Coil Quantity:
1
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 plug-in terminal single mounting facility
MRC:
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.CRPQ
Operating Current Rating And Type:
10.0 amperes ac all windings
MRC:
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
Time Delay:
10.00 seconds adjustable operate time and 10230.00 seconds adjustable operate time
MRC:
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.CSXF
Operating Voltage Rating And Type At Specificationified Temp:
120.0 volts ac 25 degrees celsius single winding
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
1 connector, receptacle all functions

Similar Electromagnetic Relaies

« Relays and Solenoids Catalog
Compare Now »
Clear | Hide