Part Number TR-1220

Reactor-transformer

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
tr-1220
Demil:
No
Shelf Life:
UOM:
NIIN:
006480757
NSN
National Stock Number:
5950-00-648-0757 5950006480757
TXT
Description:
Reactor-transformer
INC
INC
Item Name Code:
02918
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
8.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
9.469 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
6.375 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
58.0 hertz all components and 62.0 hertz all components
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single component
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
4.781 inches single mounting facili type 1st center group
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
6.250 inches single mounting facili type 2nd center group
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Type no. Pp-560/sp
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
2 all groupings
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded stud all groupings
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
1130.0 milliamperes dc single component single winding
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
0.300 1st component single winding
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
1.1 k1lovolt-amperes single component single secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
114.00 ac pounds per hour wet 2nd component single primary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
870.00 ac pounds per hour dry 2nd component single secondary and 906.00 ac pounds per hour with retaining chain 2nd component single secondary

Similar Reactor-transformers

« Coils and Transformers Catalog
Compare Now »
Clear | Hide