Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Wind speed range 0.5-20 m/sec, wind direction range 0-360 deg; microcomputer controlled; includes sensor package, balloon, electric winch w/line, and ground station
NSN
National Stock Number:
TXT
Description:
Radiosonde Set
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac/dc
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
Between 110.0 volts and 220.0 volts
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
12.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Case
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
1
MRC:
The name of the government agency or commercial organization that controls the manufacture of the accessory item.AKVY
Accessory Controlling Agency:
Atmospheric instrumentation research company
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
Airborne
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Included
MRC:
The number of complete cycle changes of radiated electromagnetic energy,per unit of time,for which an item is rated.ANKZ
Radio Frequency Rating:
403.0 megahertz
MRC:
The number of transmission paths in the item.ANLD
Frequency Channel Quantity:
2
MRC:
An indication of whether or not a crystal controlled transmitter is included.ANLF
Err Default:
Err default
MRC:
The atmospheric medium the item is designed to transmit.ANLW
Meteorological Condition Transmitted:
Pressure and temperature and wind speed and wind direction
MRC:
The measured range of atmospheric medium the item is designed to transmit.ANLZ
Meteorological Condition Transmission Range:
-50.0/+50.0 degrees celsius and +0.0/+100.0 millibars
MRC:
Indicates the type of carrier used with the item.ANMB
Err Default:
Err default