Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
ttu-131e
Demil:
No
Shelf Life:
UOM:
NIIN:
008951348

Part Information
Sampler assembly consists of the storage tank assembly which includes the tank, the filler and the extraction valve, a pressure gage and a burst disc to protect the tank from overpressure; also includes the fill hose assembly and ordnance coupling and a case; operating pressure 1800 psi ; burst disc relief pressure 2200 to 2700 psi; weight 40 lbs

NSN
National Stock Number:
6695-00-895-1348 6695008951348
TXT
Description:
Liquid Sampler
INC
INC
Item Name Code:
18960
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
15.000 inches
MRC:
An indication of whether or not a thermometer is included.AWAK
Thermometer:
Not included
MRC:
An indication of whether or not an extension tube is included.BNKB
Extension Tube:
Not included
MRC:
An indication of whether or not a gage is included.BNKC
Gage:
Included
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
3the sampler, cryogenic liquid is a small pressure vessel used to receive, vaporize and contain a sample of a cryogenic liquid from a supply source; the sampler provides a representative sample of the supply source liquid for laboratory analysis
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
16.500 inches
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
T.O. 33d2-10-60-1, 33d2-10-56-1 and 33d2-10-53-1
MRC:
Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
Special Test Features:
Clean for oxygen use
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
For general purpose use

Similar Liquid Samplers