Part Number TYPEANUPM61

Range Indicator Calibrator

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
typeanupm61
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
005649477

Part Information
T.O. 33a1-10-14-4

NSN
National Stock Number:
6625-00-564-9477 6625005649477
TXT
Description:
Range Indicator Calibrator
INC
INC
Item Name Code:
00767
INC
COM
Compliance:
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
1.0 kilohertz
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.0 hertz
MRC:
The name assigned to the item by the joint electronics type designation system.AKWA
Joint Electronics Type Designation System Item Name:
Range calibrator
MRC:
The type number assigned to the item by the joint electronics type designation system.AKWB
Joint Electronics Type Designation System Item Type Number:
Ts-102b/ap
MRC:
The total opposition (resistive and reactive) which the item offers to the output flow of alternating current.ANSR
Output Impedance Rating:
50.0 ohms
MRC:
The output voltage rating at which the item is designed to operate.AQYB
Output Voltage Rating:
30.0 volts
MRC:
Indicates the location of the input pulse.BHXP
Err Default:
Err default
MRC:
Indicates the location of the input pulse.BHXP
Input Pulse Location:
Internal
MRC:
Indicates the type of polarity of the input pulse.BHXQ
Input Pulse Polarity Type:
Positive
MRC:
Indicates the type of output polarity of the item.BHXS
Err Default:
Err default
MRC:
Indicates the type of output polarity of the item.BHXS
Output Polarity Type:
Positive
MRC:
Indicates the type of marker provided with the item.BHXT
Err Default:
Err default
MRC:
Indicates the type of marker provided with the item.BHXT
Marker Type:
Range
MRC:
The range of complete cyclic changes,per unit of time,for which the marker pulse recurrence is rated.BHXW
Marker Pulse Recurrence Frequency Range:
Between 40.0 hertz and 4.0 kilohertz
MRC:
The number of alternating current phases.FAAZ
Phase:
Single

Similar Range Indicator Calibrators

« Electrical and Electronic Properties Measuring and Testing Instruments Catalog
Compare Now »
Clear | Hide