Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
With illuminated inverted light path
NSN
National Stock Number:
TXT
Description:
Optical Microscope
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
136.000 millimeters
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
172.000 millimeters
MRC:
Indicates the designed use of the item.ALBY
Usage Design:
Chemistry
MRC:
Indicates the design type of the item.APGF
Design Type:
General purpose
MRC:
Indicates the type of focusing provided.BCTD
Focusing Type:
Adjustable
MRC:
Indicates the type of lens provided on the item.BLGP
Lens Type:
Achromatic
MRC:
The power and/or amount of apparent enlargement by an optical device.BLPR
Magnification:
850.0
MRC:
Indicates the type of nonstereoscopic unit provided.BMLT
Nonstereoscopic Type:
Binocular
MRC:
An indication of the position of the body tube.BMLW
Body Tube Position:
Inclined
MRC:
An indication of whether or not a feature for interchangeability of body tubes is provided.BMLZ
Body Tube Interchangeability Feature:
Provided
MRC:
An indication of whether or not a body tube analyzer is included.BMMB
Body Tube Analyzer:
Not included
MRC:
An indication of whether or not the body tube is provided with a bertrand lens.BMMC
Body Tube Bertrand Lens:
Not provided
MRC:
An indication of whether or not a body tube accessory slot is provided.BMMD
Body Tube Accessroy Slot:
Not provided
MRC:
The physical configuration of the stage.BMMF
Stage Shape:
Rectangular
MRC:
Indicates the type of stage provided.BMMH
Stage Type:
Mechanical
MRC:
An indication of whether or not a centering feature is provided.BMMJ
Centering Feature:
Provided
MRC:
An indication of whether or not mounted cross hairs are provided.BMSR
Mounted Cross Hairs:
Provided
MRC:
An indication of the coating feature on the lens.BMSX
Lens Coating Feature:
Coated
MRC:
An indication of whether or not a cover glass correction collar is provided.BMSZ
Cover Glass Correction Collar:
Provided
MRC:
Indicates the type of objective provided.BMTH
Objective Type:
Dry
MRC:
An indication of the stage calibration facility provided.BPFB
Stage Calibration Facility:
Graduated scale
MRC:
The design of the nosepiece.BPFK
Nosepiece Design:
Turret
MRC:
The number of objective(s) provided.BPFM
Objective Quantity:
1
MRC:
An indication of whether or not an iris diaphragm is provided on the objective.BPFQ
Objective Iris Diaphragm:
Provided
MRC:
A designation indicating the amount of apparent enlargement by the eyepiece.BPFY
Eyepiece Magnification:
8
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
As differentiated by nonstereoscopic type