Part Number V670SWH624

Steam-hot Water Hea Water Heater

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
v670swh624
Demil:
No
Shelf Life:
UOM:
NIIN:
014815092

Part Information
Heater, water, steam 670gal. 125psi 40t160deg f

NSN
National Stock Number:
4410-01-481-5092 4410014815092
TXT
Description:
Steam-hot Water Hea Water Heater
INC
INC
Item Name Code:
13711
MRC:
The maximum pressure at which an item is designed to operate.AAJJ
Maximum Operating Pressure:
125.0 pounds per square inch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
98.000 inches
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.ABKV
Outside Diameter:
78.000 inches
MRC:
The installed position for which the item is designed.ADSM
Mounting Position:
Vertical
MRC:
The rated heating capacity of the item per hour.AMHR
Heating Capacity Per Hour:
554.0 gallons
MRC:
Indicates the capacity of the tank.AMKA
Tank Capacity:
670.0 gallons
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the water inlet connection.AMLL
Water Inlet Connection Thread Size And Series/type Designator:
2in. Npt
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the water outlet connection.AMLM
Water Outlet Connection Thread Size And Series/type Designator:
2in. Npt
MRC:
The number of water inlet connections.AMLQ
Water Inlet Connection Quantity:
1
MRC:
The number of water outlet connections.AMLR
Water Outlet Connection Quantity:
1
MRC:
The maximum pressure at which the heating coil is designed to operate.AMRE
Heating Coil Maximum Operating Pressure:
125.0 pounds per square inch
MRC:
An indication of the surface area of a heating coil.AMRF
Heating Coil Surface Area:
24.000 square inches
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the heating coil inlet connection.AMRG
Err Default:
Err default
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the heating coil outlet connection.AMRH
Err Default:
Err default
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Steel
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel

Similar Steam-hot Water Hea Water Heaters

« Industrial Boilers Catalog
Compare Now »
Clear | Hide