Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Sweep Generator
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
17.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
6.875 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
16.000 inches
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
Not rated
MRC:
The maximum force at impact that the item is rated to withstand,without resulting in any permanent change in physical or electrical characteristics,expressed in gravitational units /g's/.AFDP
Shock Resistance Rating In Gravitational Units:
Not rated
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
Not rated
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
Not rated
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Manual
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Top of cabinet/counter
MRC:
Indicates the type of control.AQZF
Control Type:
Local
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
1.0 megahertz operating channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
300.0 megahertz operating channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
1.0 megahertz operating channel
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
300.0 megahertz operating channel
MRC:
Indicates the type of frequency adjustment included in the item.BHTD
Frequency Adjustment Type:
Continuous
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
0.0
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
102.0
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
Not rated
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
75.000 ohms operating channel
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
Operating channel sweep
MRC:
The limits of calbration,expressed in percent.BJBH
Calibrated Tolerance In Percent:
-1.0/+1.0
MRC:
The limits of calbration,expressed in percent.BJBH
Calibrated Tolerance In Percent:
-1.0 to 1.0
MRC:
The maximum time an item will continuously run,expressed in hours.BJBM
Maximum Continuous Operating Time In Hours:
Not rated
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
50.0 single voltage
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
60.0 single voltage
MRC:
A designation of the function which is calibrated.BJBS
Calibration Function:
Frequency
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
115.0 or 230.0 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single