Part Number W200M1CFCY4Y7

Alternating Current Motor

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
w200m1cfcy4y7
Demil:
No
Shelf Life:
UOM:
NIIN:
014555273

Part Information
Omit both class ii ground-fault protection and phase-loss protection; function, starter, antenna motor; reference data, hr2k7, ti-6310.30, fa 10084, pg 8-18, (aos)

NSN
National Stock Number:
6105-01-455-5273 6105014555273
TXT
Description:
Alternating Current Motor
INC
INC
Item Name Code:
00530
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
7.310 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
11.380 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
9.300 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Asr9, airport surveillance radar, dtfa-01-83-c-20027
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
General purpose
MRC:
The means of attaching the item.AXGY
Mounting Method:
Fixed base
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
3 threaded hole
MRC:
The amount of electrical energy that can be dissipated.CNXS
Power Rating:
7.500 horsepower input
MRC:
The nominal center to center distance between the mounting facilities parallel to the length.CWDT
Center To Center Distance Between Mounting Facilities Parallel To Length:
6.000 inches
MRC:
The nominal center to center distance between the mounting facilities parallel to the width.CWFY
Center To Center Distance Between Mounting Facilities Parallel To Width:
2.500 inches
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
120.0 line to line single input
MRC:
The number of alternating current phases.FAAZ
Phase:
Three input
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 input

Similar Alternating Current Motors