Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Wire Rope Hoist
MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Oilproof
MRC:
The maximum height the item is capable of raising an object.AGBP
Maximum Lift Height:
84.0 feet
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
The means used to operate the item.APHE
Operation Method:
Power
MRC:
The total load the item is capable of moving at selected speeds and the drum location.ATWN
Load Limit At Selected Speed And Drum Location:
2000.0 pounds single speed first drum
MRC:
The distance that the item will move per minute,per specific measurement scale.ATWP
Travel Rate Per Minute:
30.0 feet
MRC:
The means used to gain a mechanical advantage.ATWR
Mechanical Advantage Method:
Worm gear
MRC:
The means by which the braking action is applied.ATWS
Braking Method:
Electric
MRC:
The number of hooks provided.ATWT
Hook Quantity:
Any acceptable
MRC:
The number of elements per hook,which are load bearing.ATWW
Load Element Quantity Per Hook:
Any acceptable
MRC:
The distance between the centers of the load elements.ATWX
Center To Center Distance Between Load Elements:
Any acceptable
MRC:
The power required to start and operate the item at rated capacity.ATYG
Power Requirement Rating:
2.00 horsepower
MRC:
The means used in the suspension mounting of an item.AWEH
Suspension Mounting Method:
Base
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Parallel
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Air to air cooled
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
208.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0